Guards shall be located along open sided walking surfaces including mezzanines equipment platforms stairs ramps and landings that are located more than 30 inches 762 mm measured vertically to the floor or grade below at any point within 36 inches 914 mm horizontally to the edge ofthe open side.
Pa code for open sided floors.
1 inch 25 4 mm 1 foot 304 8 mm.
Existing stairways may need to be modified with new solid risers or toe board with possibly new replacement treads having nosings when solid risers are provided with new graspable handrails and or with new intermediate balusters for open stair guards to meet current code requirements.
This rule shall apply to temporary conditions where there is danger of employees or material falling through floor roof or wall openings or from stairways or runways.
A step tread is the flat horizontal surface that you walk on.
Search by information in one or all titles.
These pages provide information regarding pennsylvania s statewide building code generally known as the uniform construction code ucc.
10 to 11 inches minimum.
Headers are found in walls.
The information for the pennsylvania bulletin included at this website has been derived directly from.
Staircase tread run depth.
4000 august 1 2020.
Pre 1970 guardrail height codes railings on landings and open hallways porches screened porches balconies that are more than 30 above floors or grade.
These acts amend the pennsylvania construction code act.
Required and must be 36 high prior to 1970 in many jurisdictions.
The pennsylvania code website reflects the pennsylvania code changes effective through 50 pa b.
Although single plies are permitted they are not recommended.
They are often positioned beneath load bearing walls.
You may search the pennsylvania code online database by entering information in the box below.
4123 1 3 04 floors stairways railing overhead protection and guarding of open sided floors platforms and runways.
Act 35 of 2017 and act 36 of 2017 went into effect october 25 2017.
Enforcement of the ucc began in april 2004.
The information for the pennsylvania code included at this website has been derived directly from the pennsylvania code the commonwealth s official publication of rules and regulations cite all material in the pennsylvania code by title number and section number.
The tread depth is the distance from the front edge or nosing a tread projection that overhangs the riser below of one step to the front edge or nose of the next step measured horizontally.
Guards along open sided stairs shall be a minimum of 34.